I grew up on a farm = eat your food do not waste it! Debris from the disposal will clog your drains in enough time
read more
The illustration above shows the difference between an S-trap and a P-trap. S-traps are not permitted due to siphoning problems. Complements of www.nachi.org
read more
Truss Uplift
A home inspector may observe during a home inspection a crack in the corner of an interior ceiling made of drywall.
The crack may be at the top of the wall, and it may appear very thin or narrow (a hairline crack).
read more
Unvented Crawlspaces
In most climate zones, conditioned crawlspaces perform better than vented crawlspaces in terms of safety, health,
comfort, durability, and energy consumption. Research has demonstrated how these conditioned crawlspaces also do not
cost more to construct than vented crawlspaces. Crawlspace venting is a widely accepted business practice across the
U.S. However, in humid climates, the warm humid air entering the crawlspace is more likely to condense on crawlspace
framing than it will to help dry out the crawlspace. This is because the outside air can often have a dew point that
is higher than the interior crawlspace framing surface temperature. As evidence, existing vented crawlspaces have
experienced serious moisture and mold problems, costing builders and homeowners significant resources to repair.
read more
Hydrostatic pressure refers to the pressures caused by water pushing against slabs and foundations, particularly
underground concrete block or poured concrete walls of foundation and crawlspaces. Water is dense and weighs about
60 lbs. per cubic foot of volume and is therefore capable of generating immense hydrostatic pressure on anything
that restricts its natural movement or flow.
read more
The weight and pressure of the dry soil may affect and crack a foundation. There is wet soil that can exert a force
against a foundation.
read more
Collar Ties
Collar ties span between and connect opposing rafters, and they are typically placed in the top third of the attic spaces. Collar ties hold the rafters down against the ridge board and, to an extent, help prevent rafter spread. Home inspectors should take note of attics without collar ties, especially where the rafters run perpendicular to the joists. Collar ties must be at least 1x4 (nominal) and spaced not more than 4 feet on center. A lack of collar ties may allow roof rafters to separate and cause sagging of the roof's ridge and structure.www.nachi.org
read more
A crack that forms a V-shape may indicate heaving. The illustration above shows a V-shape open crack in a foundation wall indicating heaving from the ground under the foundation footing. The ground in the illustration is expanding and pushing upward on the footing and foundation, causing a crack. This observation by a home inspector would be reported as a major structural concern and defect with correction and further evaluation & repair by a licensed foundation contractor or structural engineer
read more
A brick wall is not necessarily considered to be waterproof. Water can penetrate through a masonry crack that is
hairline or as small as 1/100th of an inch (0.3 mm). And masonry exterior-covering materials (siding) is porous and
can absorb moisture during a weather event.
read more
inspectors should look for and note:
read more