Discharge, Loop and Air Gap
The dishwasher discharge hose should be connected to the waste tee or disposer inlet above the drain trap. It is
recommended that the drain hose either be looped up and securely fastened to the underside of the counter, or be
connected to an air gap.
read more
I grew up on a farm = eat your food do not waste it! Debris from the disposal will clog your drains in enough time
read more
The illustration above shows the difference between an S-trap and a P-trap. S-traps are not permitted due to siphoning problems. Complements of www.nachi.org
read more
Truss Uplift
A home inspector may observe during a home inspection a crack in the corner of an interior ceiling made of drywall.
The crack may be at the top of the wall, and it may appear very thin or narrow (a hairline crack).
read more
Unvented Crawlspaces
In most climate zones, conditioned crawlspaces perform better than vented crawlspaces in terms of safety, health,
comfort, durability, and energy consumption. Research has demonstrated how these conditioned crawlspaces also do not
cost more to construct than vented crawlspaces. Crawlspace venting is a widely accepted business practice across the
U.S. However, in humid climates, the warm humid air entering the crawlspace is more likely to condense on crawlspace
framing than it will to help dry out the crawlspace. This is because the outside air can often have a dew point that
is higher than the interior crawlspace framing surface temperature. As evidence, existing vented crawlspaces have
experienced serious moisture and mold problems, costing builders and homeowners significant resources to repair.
read more
Notches in the middle third of a floor joist are not permitted. Holes are not permitted to be located within 2 inches
of the top or bottom edge of a floor joist. The maximum depth of a notch in a floor joist (that is not in the middle
third of the joist) is the actual depth of the joist divided by 6. The maximum diameter of a bored hole through a
floor joist (that is not in the middle third of the joist) is the actual depth of the joist divided by 3.
read more
Crawlspaces
Access openings must be a minimum of 18 inches high by 24 inches wide. Access to all under-floor spaces must be
provided with access openings through the floor not smaller than 18 inches by 24 inches (457 mm by 610 mm).
read more
Check for downspouts diverters not discharging water far enough away from the house. Check floor lawn irrigation
systems spraying water against the house foundation, and check for gardens or planters that are up against the
house. These may be causing wet soil pressure problems for the structure.
read more