Tankless coils are indirect water heaters that take their heat from the steam or hot water boiler that is used to
heat the house. A cold-water supply pipe extends into the hottest part of the boiler water. The water in the copper
tube is kept hot by the boiler water. When there is demand for hot water, water flows through the tube through the
hot boiler water, and water is delivered to the fixture.
read more
Water circulating through a hot water circulation system becomes chemically inert and does not rust the piping. But
water heaters have a constant supply of fresh water with lots of corrosion-causing oxygen. Because of this, water
heaters are prone to corrosion. As a result, water heaters usually have an anti-corrosion rod or sacrificial rod
installed. Sacrificial anodes are typically made of magnesium or aluminum. The rod is immersed inside the water
heater tank, allowing the chemical reaction from the fresh water to attack it rather than the tank. In some areas,
rods are replaced regularly.
read more
If a laundry tub waste line connects to a clothes washer standpipe, the standpipe should be at least 30 inches above the standpipe trap weir and should extend above the flood level rim edge of the laundry tub. The outlet of the laundry tub must not be more than 30 inches horizontally away from the standpipe trap.
read more
Watch this and again NEVER skip a sewer scope! New construction also, we have found many new builds with sewer line issues
read more
Todd D. Engle, CMI
Certified Master Inspector (CMI)®
read more
I grew up on a farm = eat your food do not waste it! Debris from the disposal will clog your drains in enough time
read more
The illustration above shows the difference between an S-trap and a P-trap. S-traps are not permitted due to siphoning problems. Complements of www.nachi.org
read more
Truss Uplift
A home inspector may observe during a home inspection a crack in the corner of an interior ceiling made of drywall.
The crack may be at the top of the wall, and it may appear very thin or narrow (a hairline crack).
read more
Notches in the middle third of a floor joist are not permitted. Holes are not permitted to be located within 2 inches
of the top or bottom edge of a floor joist. The maximum depth of a notch in a floor joist (that is not in the middle
third of the joist) is the actual depth of the joist divided by 6. The maximum diameter of a bored hole through a
floor joist (that is not in the middle third of the joist) is the actual depth of the joist divided by 3.
read more